Autoclaved aerated concrete products are preferred for constructing residential, hotel, industrial, and public buildings because of their natural composition and non-toxic property, saving energy and being environmentally friendly. AAC panel usage can be infill walls. Only block thicknesses 125mm & above are suitable for use as load-bearing walls.
Landed Houses
Apartments/Condominiums
Industrial/Commercial Building
Single Mesh
Length(mm) | Houses | Apartments | Industrial | Remarks |
75mm | Internal Partitions | – | – | |
100mm | Party Wall | Internal Partitions | Perimeter Fencing | |
125mm | Internal Partitions External Wall | – | – |
Double Mesh
Length(mm) | Houses | Apartments | Industrial | Remarks |
75mm up to 3 meter | Internal Partitions Roof Starking | Internal Partitions Roof Starking | – | |
100mm up to 4 meter | Internal Partitions External Wall Party Wall Parapet Wall | Internal Partitions External Wall Party Wall Parapet Wall Staircase Wall | Internal Partitions External Wall Compartment Wall Separating Wall Acoustic Wall Parapet Wall Staircase Wall | |
125mm up to 5 meter | Internal Partitions External Wall | Internal Partitions External Wall Staircase Wall | Internal Partitions External Wall Compartment Wall Separating Wall Acoustic Wall Parapet Wall Staircase Wall | |
150mm | Party Wall | – | Internal Partitions External Wall Compartment Wall Separating Wall Acoustic Wall Parapet Wall Staircase Wall | |
200mm | Parapet Wall | – | Internal Partitions External Wall Compartment Wall Separating Wall Acoustic Wall Parapet Wall Staircase Wall |